High-speed
gel electrophoresis chamber
Click
"Order Status" above to see who are 6Mgel
users
|
Gel
electrophoresis chamber and tips of smart gel electrophoresis:
How
to run precast gel electrophoresis chamber using only 15ml running buffer?
How
to screening 96 PCR samples in 6 minute with Febe electrophoresis box?
How
to change gel length between 2cm to 12cm for agarose saving with midear
electrophoresis chamber?
Q: Why Biokeystone gel
electrophoresis chamber is irresistible ?
A: It is clear if you
know the feature of Biokeystone horizontal
gel electrophoresis chamber, Since 1994, Biokeystone invention of submarine gel
electrophoresis chamber has passed over 10 model versions. The name of the
latest model tells how Biokeystone gel electrophoresis chamber are differ from
any other gel electrophoresis chamber.
Febe
gel electrophoresis chamber
Faster
Easier Better Electrophoresis
chamber
Only
15ml running buffer for high-speed electrophoresis in 6-minute.
Cast
20 gels at once and store them for a month without any wrapping.
Have
your own precast gels ready anytime without paying high prices of
commercial gels.
Straight
banding technology eliminates gel-smiling problem.
Febe and Midear gel
electrophoresis chamber are developed from previous models below:
Super gel
electrophoresis chamber, including super 120 and super 80.
Screener gel
electrophoresis chamber, including super 13.
Scooter gel
electrophoresis chamber, including scooter 100, scooter 60.
Liberty gel
electrophoresis chamber, including liberty 1, liberty 2, liberty 4.
Q gel electrophoresis
chamber,
RAGE gel
electrophoresis chamber, including RGX100 RGX 60.
Why Biokeystone gel electrophoresis chamber
is much better than any other company's?
In agarose gel electrophoresis chamber, the apparatus
chamber holds liquid buffer, such as TAE buffer,
TBE buffer, and mops buffer. An agarose gel plate is
immersed under the conductive electrophoresis running buffer. The electrophoresis buffer conducts electric
current two electrodes of the electrophoresis chamber. Sample molecules in the
electric field migrate along a direction from negative to positive according to
their charge and molecular size. After agarose gel electrophoresis process, the
gel plate is removed from the electrophoresis box to a UV illuminator for
picturing. Sample molecules form distinguished bands in the agarose gel plate.
The conductive electrophoresis buffer in the electrophoresis
chamber, while conducting
electric current to agarose gel plate, generates undesired heat during agarose
gel electrophoresis, which limits agarose gel electrophoresis a slow process at
low voltage.
Biokeystone invents water cooling agarose gel electrophoresis
chamber, a
unique agarose gel electrophoresis box with so many advantages together, and leads agarose
gel electrophoresis industry to modern generation.