High
speed gel
electrophoresis apparatus
Click
"Order Status" above to see who are 6Mgel
users
|
Gel
electrophoresis apparatus and tips of smart gel electrophoresis:
How
to run precast gel electrophoresis apparatus using only 15ml running buffer?
How
to screening 96 PCR samples in 6 minute with Febe electrophoresis apparatus?
How
to change gel length between 2cm to 12cm for agarose saving with midear
electrophoresis apparatus?
Q: Why Biokeystone gel
electrophoresis apparatus is irresistible ?
A: It is clear if you
know the feature of Biokeystone horizontal
gel electrophoresis apparatus, Since 1994, Biokeystone invention of submarine gel
electrophoresis apparatus has passed over 10 model versions. The name of the
latest model tells how Biokeystone gel electrophoresis apparatus are differ from
any other gel electrophoresis apparatus.
Liberty
120 el electrophoresis apparatus:
Liberty 120 gel
electrophoresis apparatus are developed from previous models below:
Super gel
electrophoresis apparatus, including super 120 and super 80.
Screener gel
electrophoresis apparatus, including super 13.
Scooter gel
electrophoresis apparatus, including scooter 100, scooter 60.
Liberty gel
electrophoresis apparatus, including liberty 1, liberty 2, liberty 4.
Q gel electrophoresis
apparatus,
RAGE gel
electrophoresis apparatus, including RGX100 RGX 60.
Why Biokeystone gel electrophoresis apparatus
is much better than any other company's?
In agarose gel electrophoresis apparatus, the apparatus
chamber holds liquid buffer, such as TAE buffer,
TBE buffer, and mops buffer. An agarose gel plate is
immersed under the conductive electrophoresis running buffer. The electrophoresis buffer conducts electric
current two electrodes of the electrophoresis apparatus. Sample molecules in the
electric field migrate along a direction from negative to positive according to
their charge and molecular size. After agarose gel electrophoresis process, the
gel plate is removed from the electrophoresis apparatus to a UV illuminator for
picturing. Sample molecules form distinguished bands in the agarose gel plate.
The conductive electrophoresis buffer in the electrophoresis
apparatus, while conducting
electric current to agarose gel plate, generates undesired heat during agarose
gel electrophoresis, which limits agarose gel electrophoresis a slow process at
low voltage.
Biokeystone invents water cooling agarose gel electrophoresis apparatus, a
unique agarose gel electrophoresis apparatus with so many advantages together, and leads agarose
gel electrophoresis industry to modern generation.