Liberty
120
Agarose
Gel Electrophoresis Chamber
|
See
enlarged view of
Liberty 120 chamber - Rapid gel electrophoresis in 6 minutes
Unique features of
Liberty 120 gel chamber:
Agarose saving
-- one gel tray for three gel lengths, as shown below, long gel 12.8cm,
short gel 4.4cm, and middle gel 7.8cm. Buffer-saving -- 200ml running
buffer. Straight banding technology
Liberty 120
straight banding technology , 1 uv transparent gel tray for 3 gel lengths as
shown below

See User Feedback about the performance of buffer-less high speed electrophoresis:
" The
Liberty
bufferless gel system is the best gel electrophoresis system we've ever
used. It's not only easy to set up, robust, and fast, but generates
excellent results without the need of running buffer. Highly
recommended. See our genotyping service picture below." ---- Ivan Delgado Orlic, President and CEO,
Mouse
Genotype Co.
|

| Cat. # |
Item description |
Price |
| SYS-LBT120 |
Complete Liberty
120 gel chamber, including: 1 chamber, 1 cover, 1 gel scoop, 1 pair of power cords,
1 pair of
electrodes, and 2 combs (Cat. #
CMR-1315 & CMR-2615).
|
$498 |
| BAP-500 |
Biotech
grade
specialty agarose for high speed agarose gel electrophoresis, 500g/bottle,
DNase RNase not detectable |
$368 |
| CMS - 1307 |
13 teeth 0.7mm
thick comb, 12-channel pipette compatible, max12ul |
$26 |
| CMR - 1315 |
13 teeth 1.5mm
thick comb, 12-channel pipette compatible, max25ul |
$26 |
| CMS - 1907 |
19 teeth 0.7mm
thick comb, max8ul |
$26 |
| CMR - 1915 |
19 teeth 1.5mm
thick comb, max18ul |
$26 |
| CMS - 2607 |
26 teeth 0.7mm
thick comb, 12-channel pipette compatible, max5ul |
$26 |
| CMR - 2615 |
26 teeth 1.5mm
thick comb, 12-channel pipette compatible, max10ul |
$26 |
| CMR - 3915 |
39 teeth 1.5mm
thick comb, 12-channel pipette compatible, max 5ul |
$26 |
| |
|
|
|
|
|
6Mgel
Innovative Gel Tips
|
 |
What
is 6Mgel Confidence?
6Mgel
has been offering Guaranteed Return to all customers for 16 years.
Any gel equipments can be returned for any reason without
rejection. 6Mgel quality shows a total of 1 unit being returned
and 4 units being repaired among all units sold in past years.
|
Explore
the 6Mgel website --
You
will find techniques and tips that can help you produce data
more quickly and easily, with exceptional results.
|
----------------------------
Operation
Steps of Liberty 120 gel chamber
-
Select gel
length, long, short, or middle
-
Microwave
agarose solution in TAE or TBE, mix 2ul ethidium bromide to gel
solution, pour it into gel tray, place combs, and let the gel to
solidify.
-
Remove
combs, add 300ml deionized water on gel top and total 200ml of 1x
running buffer to chamber, and load samples into wells.
-
Run gel
220V for 6-10 minutes depending on your samples.
-
Take gel
picture after run.
|