Gel electrophoresis unit and tips of smart gel electrophoresis:

How to run precast gel electrophoresis unit using only 15ml running buffer?

How to screening 96 PCR samples in 6 minute with Febe electrophoresis unit?

How to change gel length between 2cm to 12cm for agarose saving with electrophoresis unit? 

 

                                  electrophoresis unit

The irresistible beauty of electrophoresis unit from Biokeystone

 

Febe gel electrophoresis unit   

Faster Easier Better Electrophoresis unit

Only 15ml running buffer for high-speed electrophoresis in 6-minute.

Cast 20 gels at once and store them for a month without any wrapping.

Have your own precast gels ready anytime without paying high prices of commercial gels.

Straight banding technology eliminates gel-smiling problem.

 

Midear gel electrophoresis unit:

 

Multi-gel length, Instant gel casting, Dual electrophoresis function, Easy apparatus setup, Agarose saving, and Rapid gel electrophoresis.

 

Febe and Midear gel electrophoresis unit are developed from previous models below:

 

Super gel electrophoresis unit, including super 120 and super 80.

Screener gel electrophoresis unit, including super 13.

Scooter gel electrophoresis unit, including scooter 100, scooter 60.

Liberty gel electrophoresis unit, including liberty 1, liberty 2, liberty 4.

Q gel electrophoresis unit

RAGE gel electrophoresis unit, including RGX100 RGX 60.

Why Biokeystone gel electrophoresis unit is the best?

In agarose gel electrophoresis unit, the system chamber holds liquid buffer, such as TAE buffer, TBE buffer, and mops buffer. An agarose gel plate is immersed under the conductive electrophoresis running buffer. The electrophoresis buffer conducts electric current two electrodes of the electrophoresis system. Sample molecules in the electric field migrate along a direction from negative to positive according to their charge and molecular size. After agarose gel electrophoresis process, the gel plate is removed from the electrophoresis equipment  to a UV illuminator for picturing. Sample molecules form distinguished bands in the agarose gel plate. 

The conductive electrophoresis buffer in the electrophoresis system, while conducting electric current to agarose gel plate, generates undesired heat during agarose gel electrophoresis, which limits agarose gel electrophoresis a slow process at low voltage.

Biokeystone invents water cooling agarose gel electrophoresis system, a unique agarose gel electrophoresis equipment with so many advantages together, and leads agarose gel electrophoresis industry to modern generation.