| Gel electrophoresis systems and tips of smart gel electrophoresis:How to run precast gel electrophoresis systems using only 15ml running buffer? How to screening 96 PCR samples in 6 minute with Febe electrophoresis systems? How to change gel length between 2cm to 12cm for agarose saving with electrophoresis systems?
Febe gel electrophoresis systems
Faster Easier Better Electrophoresis systems Only 15ml running buffer for high-speed electrophoresis in 6-minute. Cast 20 gels at once and store them for a month without any wrapping. Have your own precast gels ready anytime without paying high prices of commercial gels. Straight banding technology eliminates gel-smiling problem.
Midear gel electrophoresis systems:
Multi-gel length, Instant gel casting, Dual electrophoresis function, Easy apparatus setup, Agarose saving, and Rapid gel electrophoresis.
Febe and Midear gel electrophoresis systems are developed from previous models below:
Super gel electrophoresis systems, including super 120 and super 80. Screener gel electrophoresis systems, including super 13. Scooter gel electrophoresis systems, including scooter 100, scooter 60. Liberty gel electrophoresis systems, including liberty 1, liberty 2, liberty 4. Q gel electrophoresis systems RAGE gel electrophoresis systems, including RGX100 RGX 60. Why Biokeystone gel electrophoresis systems areIn agarose gel electrophoresis systems, the systems chamber holds liquid buffer, such as TAE buffer, TBE buffer, and mops buffer. An agarose gel plate is immersed under the conductive electrophoresis running buffer. The electrophoresis buffer conducts electric current two electrodes of the electrophoresis systems. Sample molecules in the electric field migrate along a direction from negative to positive according to their charge and molecular size. After agarose gel electrophoresis process, the gel plate is removed from the electrophoresis equipment to a UV illuminator for picturing. Sample molecules form distinguished bands in the agarose gel plate. The conductive electrophoresis buffer in the electrophoresis systems, while conducting electric current to agarose gel plate, generates undesired heat during agarose gel electrophoresis, which limits agarose gel electrophoresis a slow process at low voltage. Biokeystone invents water cooling agarose gel electrophoresis systems, a unique agarose gel electrophoresis equipment with so many advantages together, and leads agarose gel electrophoresis industry to modern generation. |